APC SURT1000XLI-CH Smart UPS RT 1000, ON-LINE,Tower/Rackmount 2U,Replacement battery cartridgeRBC31,208/230V, 6x IEC C13+1x IEC jumper, USB and Serial communication, AVR, Graphic LCD,Network Card

Purchase Support +0086 19710409880 Albert

This APC Smart-UPS RT is designed for IT professionals or network administrators to maintain business uptime and continuity. This 1kVA on-line tower/rackmount UPS provides pure sine wave power and extended runtime to support critical electronics during power disruptions. It comes with IEC 60320 C14 inputs, 6x IEC 320 C13 and 1x 1 IEC Jumpers outlets. It has a SmartSlot for optional Network Management Card that enables graceful shutdown of physical servers, virtual machines & HCI Clusters via PowerChute Network Shutdown. The UPS can connect to EcoStruxure IT or third-party centralized management platforms. The UPS has a 2-year warranty, and the built-in lead-acid battery RBC31 has a 1-year warranty. The UPS is compatible with SRTRK4 (4-post) and SRTRK3 (2-post) rail kits sold separately.

APC Smart UPS online 1000VA-SURT1000XLI-CH

APC SMART UPS RT Series Products Order Checklist
Standard Model with
 Built-in Battery
Product Feature Description
SURT1000XLI-CH(2U)APC SMART UPS RT 1000VA/900W;230VAC;LCD Display; 48VDC
SURT2000XLI-CH(2U)APC SMART UPS RT 2000VA/1800W;230VAC;LCD Display; 48VDC
SURT3000XLI-CH(3U)APC SMART UPS RT 3000VA/2700W;230VAC;LCD Display; 96VADC
SURT5000XLI-CH(3U)APC SMART UPS RT 5000VA/5000W;230VAC;LCD Display; 192VDC
SURT6000XLI-CH(3U)APC SMART UPS RT 6000VA/6000W;230VAC;LCD Display; 192VDC
SURT8000XLI-CH(6U)RT 8000VA/8000W;Single-phase 230VAC;Three-phase 380VAC;
LCD Display; ±192VDC
SURT10000XLI-CH(6U)RT 10000VA/10000W;Single-phase 230VAC;Three-phase 380VAC;
LCD Display; ±192VDC
 Extended Runtime ModelProduct Feature Description
SURT1000UXI-CH(2U)APC SMART UPS RT 1000UX/900W;230VAC;
LCD Display; Extended 48VDC
SURT2000UXI-CH(2U)APC SMART UPS RT 2000UX/1800W;230VAC;
LCD Display;Extended 48VDC
SURT3000UXI-CH(3U)APC SMART UPS RT 3000UX/2700W;230VAC;
LCD Display;Extended 96VDC
SURT5000UXI-CH(3U)APC SMART UPS RT 5000UX/5000W;230VAC;
LCD Display;Extended 192VDC
SURT6000UXI-CH(3U)APC SMART UPS RT 6000UX/6000W;230VAC;
LCD Display;Extended 192VDC
SURT8000UXI-CH(6U) RT 8000UX/8000W;Single-phase 230VAC;Three-phase 380VAC;
LCD Display;Extended ±192VDC
SURT10000UXI-CH(6U)RT 10000UX/10000W;Single-phase 230VAC;Three-phase 380VAC;
LCD Display;Extended ±192VDC
SURT15KUXI-CH(6U) RT 15000UX/15000W;Single-phase 230VAC;Three-phase 380VAC;
LCD Display;Extended ±192VDC
SURT20KUXI-CH(6U) RT 20000UX/20000W;Single-phase 230VAC;Three-phase 380VAC;
LCD Display;Extended ±192VDC
Extended Battery PackProduct Feature Description
SURT48XLBP-CH(2U)Extended Battery Pack for  SURT1000/2000
SURT96XLBP-CH(3U)Extended Battery Pack for  SURT3000
SURT192XLBP-CH(3U)Extended Battery Pack for  SURT5K/6K/8K/10K
SURT192XLBP2-CH(6U)Extended Battery Pack for  SURT15K/20K
Replace Battery CartridgeProduct Feature Description
RBC31Replace By APCRBC48BP-CH  
Replace Battery Cartridge for SURT1000XLICH/SURT2000XLICH 
RBC44Replace By APCRBC140 
Replace Battery Cartridge for  SURT3000XLICH/5K/6K/8K/10K
APCRBC140Replace Battery Cartridge for SURT3K/5K/6K/8K/10K/SURT96XLBP-CH/
SURT192XLBP-CH/SURT192XLBP2-CH
APCRBC48BP-CHReplace Battery Cartridge for SURT1K/2K/SURT48XLBP-CH
APCRBC96BP-CHReplace Battery Cartridge for SURT3K/SURT96XLBP-CH
APCRBC192BP-CHReplace Battery Cartridge for SURT5K/6K/8K/10K/
SURT192XLBP-CH/SURT192XLBP2-CH
Rack-mounted 
Installation Accessories
Product Feature Description
SURTRK-CHSuitable for SURT1K/2K/SURT48XLBP-CH
SURTRK2-CHSuitable for SURT3K/5K/6K/SURT96XLBP-CH/SURT192XLBP-CH
SURTRK3-CHSuitable for SURT8K/10K/15K/20K/SURT192XLBP2-CH
Power Management 
Accessories
Product Feature Description
AP9641Third-generation network management card 
with environmental monitoring capabilities, 
supports SNMP, Modbus TCP, and BACnet 
(built-in for 5-20kVA models).
AP9640Third-generation network management card, 
supports SNMP, Modbus TCP, and BACnet.
AP9643Third-generation network management card 
with environmental monitoring and Modbus
 support, compatible with SNMP, Modbus TCP,
 Modbus RTU, and BACnet.
AP9613Relay Input/Output Card
AP9810Relay Input/Output Accessory, provides additional
 dry contact interfaces for network 
management cards such as AP9641/AP9643.
AP9834Provides Wi-Fi support for network management
 cards such as AP9641/AP9643.

- Product Model: 900W

- Rated Power: 900 watts

- Input Voltage: Main input voltage is 230V, with other input voltages ranging from 220V to 240V.

- Output Voltage: Main output voltage is 230V, with other output voltages ranging from 220V to 240V.

- Input Connection Type: IEC 60320 C14

- Output Connection Type: 6 IEC 60320 sockets and 1 IEC jumper

- Rack Units: 2U

- Battery Type: Lead-acid battery

- Typical Charge Time: 2.5 hours

- Included Accessories: Software CD, Smart-UPS RS232 signal cable, user manual

- Runtime: 7 minutes and 38 seconds (under full load conditions)

- Maximum Utilization: 100%

- Configurable Output Voltage: 220V, 230V, or 240V

- Battery Lifespan: 3 to 5 years

- Rated Battery Power: 90 watts

- Venturi Pipe: RBC31

- Supported Battery Options: SURT48XLBP series, with capacities ranging from 860 VAh to 6575 VAh

- Automatically Detectable and Expandable Delay Time: 1 minute

- Color: Black

- Dimensions: Height 43.2 cm, Width 8.5 cm, Depth 48.3 cm

- Weight: 23 kg

- Installation Position: Front-facing, supports rack-mounted and two-post mountable

- Input Frequency: 50/60 Hz, auto-sensing

- Input Voltage Range: 160V to 280V

- Output Power:900W

- Harmonic Distortion: Less than 3%

- Output Frequency: 50/60 Hz +/- 3 Hz, user-adjustable

- Topology: Double-conversion online

- Waveform Type: Sine wave

- Power Efficiency: 88% (full load)

- Communication and Management: Features 1 idle slot, alarm function, optional emergency shutdown

- Surge Protection Energy: 420 joules

- Packaging Unit: Single packaging unit

- Warranty Period: 2 years with repair or replacement within, optional on-site warranty available as well

This device is primarily used for providing power protection, especially during power instability or outages, to ensure a stable power supply to connected equipment. It also offers some management and communication features for monitoring and controlling its performance. Additionally, it supports a certain amount of battery backup time to continue powering devices during power interruptions.