How does the Automatic Transfer Switch (ATS) work in conjunction with UPS power to achieve dual utility input conditions?

ATS (Automatic Transfer Switch) is a power device used to automatically switch power supply in case of main power failure or instability, ensuring the continuity and reliability of electrical power. ATS has the following main functions:


1. Power switching: ATS can monitor the voltage and frequency of the main power supply. Once an abnormal condition is detected (such as voltage below or above the set threshold, frequency deviation from the normal range, etc.), ATS automatically switches the power to the backup power source, such as UPS (Uninterruptible Power Supply) or generator. This switching process is typically completed within milliseconds to ensure continuous power supply and prevent equipment from shutting down due to power interruption.


2. Power monitoring: ATS can real-time monitor the status of the main power supply and backup power source, including voltage, frequency, phase sequence, etc. By monitoring the power parameters, ATS can promptly detect abnormalities in the main power supply and take corresponding switching actions to ensure the reliability of power supply to the equipment.


3. Switching priority: ATS can be configured with different switching priorities to meet specific requirements. For example, the main power supply can be set as the preferred power source, and switching to the backup power source only occurs when the main power supply is unavailable. Alternatively, the backup power source can be set as the preferred power source, and switching back to the main power supply only occurs when the backup power source is unavailable. Flexible priority configurations allow managing power switching processes based on actual situations and needs.


4. Remote monitoring and control: Some advanced ATS devices support remote monitoring and control functions, enabling remote monitoring, parameter setting, and switching operations through network connections. This allows operations personnel to conveniently manage ATS devices remotely, improving manageability and maintenance efficiency.


UPS (Uninterruptible Power Supply) and ATS (Automatic Transfer Switch) are commonly used devices in data center power systems, and they can be used together to provide reliable power supply.


The primary function of UPS is to provide instant backup power in case of utility power failure, ensuring the uninterrupted operation of data center equipment. UPS converts the power to DC and stores it in batteries, then converts the DC power back to AC power to supply the equipment, preventing power disruptions caused by utility failures or fluctuations.


The primary function of ATS is to automatically switch to the backup power source, such as UPS or generator, in case of main power failure or instability. ATS monitors the voltage and frequency of the main power supply and swiftly switches to the backup power source when any abnormality is detected.


In a data center, UPS and ATS are often used in conjunction. Their connection is as follows:


1. UPS connected to ATS: UPS serves as the backup power source and is connected to the backup power input port of the ATS. When the main power supply fails or becomes unstable, the ATS receives a signal and switches to UPS power supply.


2. ATS connected to the main power supply and backup power source: ATS has two input ports, one connected to the main power supply and the other connected to UPS or other backup power sources. ATS monitors the status of the main power supply and automatically switches to the backup power source if a main power failure is detected, ensuring continuous power supply.


With this configuration, when the main power supply fails or becomes unstable, the ATS automatically switches to UPS power supply to maintain the normal operation of data center equipment. This dual protection mechanism ensures the reliability and continuity of the data center.


It is important to note that the selection and configuration of UPS and ATS should be based on the specific requirements and load conditions of the data center. Ensure that the capacity and performance of UPS and ATS are suitable for the power requirements of the data center, providing reliable power protection. Additionally, regular maintenance and testing of UPS and ATS devices are necessary to ensure their proper functioning and reliability.